We are ready to help!
Michael Kohlhaassales@dsa.de
+49 (0) 2408 9492-0
The electrical testing of the individual battery modules before installation ensures their function and resilience.
In addition, by means of the HVBT, the tightness of the cooling circuits and of the housing of the HV battery can be checked.
In order to identify contact resistances, the HVBT can control systems for high-current charge-discharge cycles. Optionally, faulty connections between individual battery modules can be thermographically identified by means of intelligent image analysis.
Safety-related assembly errors and defective components must be identified before installing the HV battery in the vehicle. For this purpose, the HVBT carries out the necessary high-voltage insulation tests.
The HVBT verifies and flashes the firmware of the ECUs if necessary. Here, the device provides extensive residual bus simulations. To check the battery management system (BMS), low-current charge-discharge cycles can be initiated.